Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1975 4
1977 1
1978 4
1979 2
1980 1
1981 3
1982 3
1983 2
1984 5
1985 14
1986 2
1987 7
1988 12
1989 18
1990 11
1991 14
1992 28
1993 12
1994 17
1995 21
1996 24
1997 21
1998 27
1999 18
2000 29
2001 32
2002 37
2003 28
2004 40
2005 52
2006 47
2007 55
2008 48
2009 56
2010 64
2011 71
2012 91
2013 82
2014 71
2015 93
2016 83
2017 83
2018 89
2019 110
2020 124
2021 111
2022 160
2023 145
2024 64

Text availability

Article attribute

Article type

Publication date

Search Results

1,980 results

Results by year

Filters applied: . Clear all
Page 1
Skin Impedance Estimation System for Voltage-mode Electrical Stimulator with an AC Bridge Circuit.
Matsui H, Ohnishi K, Cho SG. Matsui H, et al. Annu Int Conf IEEE Eng Med Biol Soc. 2023 Jul;2023:1-4. doi: 10.1109/EMBC40787.2023.10340064. Annu Int Conf IEEE Eng Med Biol Soc. 2023. PMID: 38083380
Voltagemode stimulators have the advantage that there is little risk of burns even if the electrode is partially detached. To perform arbitrary current-mode stimulation with voltage-mode stimulators, it is necessary to generate a stimulating voltage based on the ski …
Voltagemode stimulators have the advantage that there is little risk of burns even if the electrode is partially detached. To perform arbitr …
An impedance matching algorithm for common-mode interference removal in vagus nerve recordings.
Levy TJ, Ahmed U, Tsaava T, Chang YC, Lorraine PJ, Tomaio JN, Cracchiolo M, Lopez M, Rieth L, Tracey KJ, Zanos S, Zanos TP. Levy TJ, et al. J Neurosci Methods. 2020 Jan 15;330:108467. doi: 10.1016/j.jneumeth.2019.108467. Epub 2019 Oct 22. J Neurosci Methods. 2020. PMID: 31654663 Free PMC article.
The ability to accurately record these signals is challenging, due to the presence of various biological and instrument-related interference sources. NEW METHOD: We developed a common-mode interference rejection algorithm based on an impedance matching approach for …
The ability to accurately record these signals is challenging, due to the presence of various biological and instrument-related interference …
Scanning Electrochemical Impedance Microscopy in Redox-Competition Mode for the Investigation of Antibodies Labelled with Horseradish Peroxidase.
Zinovicius A, Morkvenaite-Vilkonciene I, Ramanaviciene A, Rozene J, Popov A, Ramanavicius A. Zinovicius A, et al. Materials (Basel). 2021 Jul 31;14(15):4301. doi: 10.3390/ma14154301. Materials (Basel). 2021. PMID: 34361494 Free PMC article.
Electrochemical impedance shows to be related to the consumption of hydrogen peroxide at the ultramicroelectrode. ...Additionally, the applicability of RC-SEIM mode for the determination of Ab-HRP affinity bound to the target analyte was discussed....
Electrochemical impedance shows to be related to the consumption of hydrogen peroxide at the ultramicroelectrode. ...Additionally, th …
Short-Time Impedance Spectroscopy Using a Mode-Switching Nonsinusoidal Oscillator: Applicability to Biological Tissues and Continuous Measurement.
Yamaguchi T, Ogawa E, Ueno A. Yamaguchi T, et al. Sensors (Basel). 2021 Oct 20;21(21):6951. doi: 10.3390/s21216951. Sensors (Basel). 2021. PMID: 34770258 Free PMC article.
Herein, we propose an impedance spectroscopy method using a mode-switching nonsinusoidal oscillator and apply this method for measuring the impedance of biological tissues and continuous impedance measurement. ...This oscillator could periodically swit …
Herein, we propose an impedance spectroscopy method using a mode-switching nonsinusoidal oscillator and apply this method for …
Model-free robust adaptive integral sliding mode impedance control of knee-ankle-toe active transfemoral prosthesis.
Wu Z, Chen Y, Geng Y, Wang X, Xuan B. Wu Z, et al. Int J Med Robot. 2022 Jun;18(3):e2378. doi: 10.1002/rcs.2378. Epub 2022 Feb 22. Int J Med Robot. 2022. PMID: 35133713
METHODS: Firstly, combined with time delay estimation (TDE), a model-free robust integral sliding mode impedance controller is designed. This method not only suppress the impedance error, but also eliminate the nonlinear relationship and disturbance in the dy …
METHODS: Firstly, combined with time delay estimation (TDE), a model-free robust integral sliding mode impedance controller is …
Cross-mode bioelectrical impedance analysis in a standing position for estimating fat-free mass validated against dual-energy x-ray absorptiometry.
Huang AC, Chen YY, Chuang CL, Chiang LM, Lu HK, Lin HC, Chen KT, Hsiao AC, Hsieh KC. Huang AC, et al. Nutr Res. 2015 Nov;35(11):982-9. doi: 10.1016/j.nutres.2015.08.005. Epub 2015 Sep 1. Nutr Res. 2015. PMID: 26409342
We compared the cross-mode with the hand-to-foot mode (right hand to right foot, Z(HF)) using dual-energy x-ray absorptiometry (DXA) as the reference. We hypothesized that when comparing anthropometric parameters using stepwise regression analysis, the impedance
We compared the cross-mode with the hand-to-foot mode (right hand to right foot, Z(HF)) using dual-energy x-ray absorptiometry …
[Study on Impedance of Implantable Cardiac Pacemaker in Unipolar/Bipolar Pacing Mode by in Vitro Experiment].
Ding D, Lin KB, Huang D, Guo XW, Wang YP, Li S, Li JB, Niu JH. Ding D, et al. Zhongguo Yi Liao Qi Xie Za Zhi. 2022 May 30;46(3):237-241. doi: 10.3969/j.issn.1671-7104.2022.03.001. Zhongguo Yi Liao Qi Xie Za Zhi. 2022. PMID: 35678428 Chinese.
The unipolar/bipolar pacing mode of pacemaker is related to its circuit impedance, which affects the battery life. ...The results of in vitro experiments showed that under the experimental conditions similar to clinical human parameters, the difference between the c …
The unipolar/bipolar pacing mode of pacemaker is related to its circuit impedance, which affects the battery life. ...The resu …
xCELLanalyzer: A Framework for the Analysis of Cellular Impedance Measurements for Mode of Action Discovery.
Franke R, Hinkelmann B, Fetz V, Stradal T, Sasse F, Klawonn F, Brönstrup M. Franke R, et al. SLAS Discov. 2019 Mar;24(3):213-223. doi: 10.1177/2472555218819459. Epub 2019 Jan 25. SLAS Discov. 2019. PMID: 30681906 Free article.
Mode of action (MoA) identification of bioactive compounds is very often a challenging and time-consuming task. We used a label-free kinetic profiling method based on an impedance readout to monitor the time-dependent cellular response profiles for the interaction o
Mode of action (MoA) identification of bioactive compounds is very often a challenging and time-consuming task. We used a label-free
Separation of Heart and Lung-related Signals in Electrical Impedance Tomography Using Empirical Mode Decomposition.
Cheng KS, Su PL, Ko YF. Cheng KS, et al. Curr Med Imaging. 2022;18(13):1396-1415. doi: 10.2174/1573405618666220513130834. Curr Med Imaging. 2022. PMID: 35570528 Free PMC article.
BACKGROUND: Electrical impedance tomography (EIT) can be used for continuous monitoring of pulmonary ventilation. ...METHODS: Our approach combines the advantages of the principal component analysis (PCA) and processes that originally measure EIT data instead of handling a …
BACKGROUND: Electrical impedance tomography (EIT) can be used for continuous monitoring of pulmonary ventilation. ...METHODS: Our app …
A fast impedance-based antimicrobial susceptibility test.
Spencer DC, Paton TF, Mulroney KT, Inglis TJJ, Sutton JM, Morgan H. Spencer DC, et al. Nat Commun. 2020 Oct 21;11(1):5328. doi: 10.1038/s41467-020-18902-x. Nat Commun. 2020. PMID: 33087704 Free PMC article.
The bacteria are incubated in the presence of an antibiotic for 30 min, and then approximately 10(5) cells are analysed one-by-one with microfluidic impedance cytometry for 2-3 min. The measured electrical characteristics reflect the phenotypic response of the bacteria to …
The bacteria are incubated in the presence of an antibiotic for 30 min, and then approximately 10(5) cells are analysed one-by-one with micr …
1,980 results